Liebert
UPStation GXT Features:
|
|
On-Line design means that the Liebert GXT corrects for frequency deviations in the input power. Power quality experts tell us that the power grid in the United States and most of Western Europe does not experience frequency deviations. These grids are rock solid 60 Hz (50 Hz for Europe). So why is protection from input frequency changes important? Good question! Allow us to answer:
OK, so the Liebert GXT corrects for frequency, what do the other off-line or line interactive systems do when frequency varies? Another good question! These systems either:
This means that with the Liebert UPStation GXT, you can develop a uniform UPS performance specification which includes the special needs for international installations, plus will assure trouble-free operation on emergency diesel power now or in the future! We've told you what the competition does (really doesn't do). What exactly does the Liebert GXT do? The Liebert UPStation corrects for the following input power problems WITHOUT USING THE BATTERY:
This all means that the GXT corrects power when it's available, preserving valuable battery energy for critical power outages. |
|
Liebert GXT UPS Specifications |
|||||
| Part Number | Rating (VA/W) | Type | Voltage | Backup Time (FL/HL) | Listing |
| GXT700MT-120 | 700/490 | Mini-Tower | 120 VAC | 5min/16min | UL / c-UL |
| GXT700MT-230 | 700/490 | Mini-Tower | 230 VAC | 6min/18min | TUV / CE |
| GXT1000MT-120 | 1000/700 | Mini-Tower | 120 VAC | 7min/19min | UL / c-UL |
| GXT1000MT-230 | 1000/700 | Mini-Tower | 230 VAC | 6min/18min | TUV / CE |
| GXT1000RT-120 | 1000/700 | Rack/Tower (1) | 120 VAC | 7min/19min | UL / c-UL |
| GXT1000RTE-120 | 1000/700 | Rack/Tower (1) | 120 VAC | 18min/50min | UL / c-UL |
| GXT1000RT-230 | 1000/700 | Rack/Tower (1) | 230 VAC | 6min/18min | TUV / CE |
| GXT1000RTE-230 | 1000/700 | Rack/Tower (1) | 230 VAC | 17min/49min | TUV / CE |
| GXT1500RT-120 | 1500/1050 | Rack/Tower (1) | 120 VAC | 5min/15min | UL / c-UL |
| GXT1500RTE-120 | 1500/1050 | Rack/Tower (1) | 120 VAC | 15min/----- | UL / c-UL |
| GXT1500RT-230 | 1500/1050 | Rack/Tower (1) | 230 VAC | 5min/15min | TUV / CE |
| GXT1800RT-208 | 1800/1260 | Rack/Tower (1) | 208 VAC | 11min/27min | UL / c-UL |
| GXT2000RT-120 | 2000/1400 | Rack/Tower (1) | 120 VAC | 11min/27min | UL / c-UL |
| GXT2000RT-230 | 2000/1400 | Rack/Tower (1) | 230 VAC | 11min/27min | TUV / CE |
| GXT2700RT-208 | 2700/1890 | Rack/Tower (1) | 208 VAC | 6min/15min | UL / c-UL |
| GXT3000RT-120 | 3000/2100 | Rack/Tower (1) | 120 VAC | 6min/15min | UL / c-UL |
| GXT3000RT-230 | 3000/2100 | Rack/Tower (1) | 230 VAC | 6min/15min | TUV / CE |
| Note 1. To mount as a rack unit a side rail kit (#RS400) is necessary. | |||||